The float level valve is the stop valve of the water tower. If the water tower overflows, it may be caused by the failure of the float valve. The failure of the float valve may be caused by excessive water pressure or unclean water source. The user uses the pumping motor to directly go to the top floor water tower. If the water is still pumped when the water is stopped, the negative pressure of the tap water pipe will be caused, and the contaminated dirty water will be pumped when the water is re-watered, and the floating ball feeder will be blocked by scale and malfunction. The user can clean up the scale by himself and restore the normal function of the float valve.
目錄
After installing the float valve, confirm that the water stop function is normal
Float level valve-failure may be caused by water pressure, or it may be blocked by scale. When the floating ball inlet is just installed, first confirm whether the water stop function of the floating ball inlet is normal. The test method is to gently pull up the white iron rod of the valve body. If the water stop is normal, it means that the float valve has no problem in its function of resisting water pressure. Therefore, when the water tower overflows in the future, it can be judged whether there is water in other places.
Click on the video below to understand the normality of testing the water stop function of the float valve
When installing the float valve, pay attention to the angle of installation of the float valve and whether there is any buoyancy caused by the float. If the pole is perpendicular to the water surface, the float will not be able to generate leverage. Please adjust the angle of the float valve or the elbow of the water tower, as shown in the figure below.
1. East Star stainless steel float valve, pay attention to the angle of the elbow of the water tower
When installing the elbow of the water tower of the float valve, pay attention to the angle. The schematic diagram is as follows.
2. Any adjustment type – pay attention to the angle of the ABS float valve:Any adjustment type can adjust any angle, but the adjustment angle should pay attention to the correct direction.
The moment is perpendicular to the water surface, there is no leverage Please adjust the angle of the pole
Float level valve-balanced float valve is generally able to resist the high water pressure of tap water. After so many years of release, thousands of customers have used it in the following situations: too high water pressure causes the float valve to fail. Few, mostly caused by other reasons. It is common that there is dirt when the water enters, and the valve is stuck, causing malfunction.
There are many reasons why the float valve cannot stop the water Find out the real reason why the floating ball cannot stop the water in order to get it done once and for all
Float level valve-control switch failure-scale blockage
Floating ball valve -turbidity is generated, sometimes when the construction site has just worked and the water source is not clean. In addition, during the construction, the leak stop belt and glue are not cleaned up, and they flow to the water tower as the water enters and get stuck. The valve of the water inlet valve is on, and after the water level is full, the valve cannot be closed, thus malfunctioning.
The construction site has just worked, and the water source is not clean The stop tape, the glue is not cleaned
Or the lime or filth caused by the tap water blocked the valve. Tap water in many areas is seriously calcareous, such as Nantou, Changhua, Pingtung and other places. After the tap water is boiled, it is not transparent, but white and turbid, with white suspended solids floating. In these areas with serious lime quality, when the water tower enters the water, the carried scale will block the valve and cause the water tower to overflow.
Some users use the pumping motor to directly go to the top-floor water tower, and it is also easy to pump contaminated dirty water due to the negative pressure of the tap water pipe, which makes the floating ball feeder malfunction due to dirty blockage.
Float level valve-scale cleaning method
The common reason for the failure of the floating ball inlet is that the dirt of the water source jams the valve, which makes the switch unable to be tight, causing the water tower inlet to fail to stop the water. If the user has used the balanced float valve for a period of time, it is caused by the blockage of scale, do not think that the float inlet is malfunctioning, because the scale can be cleaned by itself.
When the floating ball valve is blocked by scale and fails, please swing the white iron rod up and down several times to let the scale flow out with the water source. If it still doesn’t work, then you can disassemble the floating ball feeder-the main body to remove the internal scale. The design structure of the balanced float water inlet can disassemble the main parts by itself to remove the dirt inside the float valve.
The user can loosen the four screws from the water outlet of the water inlet, as shown in Figure 3 after disassembly. Then remove the dirt inside the balance rod, and the float valve can be used normally.
Balanced float valve There are four screws to connect Dismantling to remove scale
If there are many impurities in the water source of the house, regular cleaning of the inside of the floating ball inlet is the only way to keep the floating ball of the home water tower used for a long time.
Clean up the scale Water stop function is normal
It is not easy to make the floating ball valve malfunction. As long as you know how to clean up the internal dirt, the floating ball feeder can accompany you for a long time.
Float water inlet-two-stage fully open and fully closed-no scale
In addition, if the water quality in your home is poor, and there is often scale blocking the water inlet, causing the float valve to leak, then you can consider using-East star fully open and fully close the float, the valve will be fully opened instantly to discharge the scale impurities and will not block the entry Water switch.
The floating ball liquid level valve-East star fully open and fully closed, is a two-stage automatic water inlet valve, which will close the valve immediately when the water level is full, unlike the traditional water inlet that slowly stops the water, so there will be no water shock. The valve will be opened immediately at the lowest water level, and it is not easy to accumulate scale and cause the valve to malfunction.
Float valve – Other causes of water tower overflow
The floating ball feeder is made of rubber to stop the water. If closing the valve can stop the water, it can be judged that the overflow is not caused by the valve body, which may be caused by the water quality. For the Velociraptor float valve, it is used in tap water. If you use it in an oil tank or some greasy liquid surface environment, it will malfunction and overflow. Inform the manufacturer at the time of shipment that replacing the rubber suitable for the oil body is the solution.
In addition, the water source of the water tower has three inlets and outlets, namely the inlet pipe, where the float valve is installed; as well as the drain pipe and the water supply pipe. Therefore, in addition to the possibility of the failure of the float valve, the overflow of the water tower may also be caused by the overflow of the water supply pipe. There is a Kaohsiung customer who still overflows after changing the float valve. I asked her to confirm the water stop function of the float valve and confirm that it is normal. This means that the water tower overflows from other pipelines. After several investigations by her, there really was another cause.
The water tower has three pipelines connecting the outside When the check valve is broken, the water tower will overflow
There is a motor under the water tower of her house that is no longer in use, but there is a pipeline leading to the bottom of the water tower. She stopped the water at the water inlet and turned off all the taps in the house. She checked the water meter but it was still turning, indicating that the water entered the water tower from other places. After several inspections, it was found that the water ingress was the water supply pipeline from the motor to the water tower. The pressurized motor is usually not in use, but the water source will still push water into the water tower from below, that is, the check valve is broken, causing the water source to invert and the water tower overflows.
Balanced float valve can resist high water pressure
In summary, the reason for the overflow of the water tower is not just the failure of the floating ball feeder, it may be that there is water leakage in other places and you have not noticed it. In addition, the smaller the amount of influent water, it may also be a problem with the front-end pipeline, which needs to be carefully investigated. As Guo Taiming said: The devil is hidden in the details.
There is a long pipe from the water meter to the water storage tank, not all problems are in the float valve.
The floating ball of balanced design is ordinary, resistant to high pressure and not easily damaged by water pressure. In the event of a failure of the water inlet, you should first understand the water environment so that you can improve the water storage facilities of your home once and for all.
If you are really worried about the water pressure being too high to stop the water, you can strengthen the rod of the other part, increase the float, and install a pressure relief valve to counter the higher water pressure.
In summary, the reasons for the abnormality of the float are sorted out as follows:
試水情形 | 可能狀況 | 解決方式 |
---|---|---|
浮球桿子上扳無法止漏 | 橡皮有雜質塞住 | 用清水沖洗橡皮,重新測試止漏功能,如正常止水,就請加裝過濾器篩除雜質。 |
水壓太大 | 加長桿子、加大浮球 | |
使用在非自來水的特殊液體 | 請通知原廠液體成分,以使用合適的產品。 | |
橡皮損壞 | 退換產品,讓原廠檢查產品故障原因。 | |
浮球桿子上扳可以止漏 | 水塔配管其他地方漏水 | 檢查逆止閥等配管另件,是否有損壞 |
桿子垂直水面,無槓桿作用力 | 將桿子調整角度,讓其可以自然浮上水面。 | |
浮球有進水 | 打開瓶蓋,如果浮球有進水,更換浮球蓋子上的止漏墊圈。 | |
如果是很用力上扳才能止漏,那就檢查是雜質問題,還是水壓過大所致 | 同上述提到橡皮有雜質塞住、水壓太大的解決方式 |